AIS
Indoor, dual wall adhesive-lined polyolefin tubing
Technical Data |
Property
|
Test Method
|
Typical Data
|
Tensile
Strength
|
ASTM D 2671
|
10.4 MPa (min.)
|
Tensile
strength after aging 158℃, 168hrs.
|
ASTM D 2671
|
Remains 70 %
|
Elongation
at break
|
ASTM D 2671
|
300 %(min.)
|
Elongation
at break after aging 158℃, 168hrs.
|
ASTM D 2671
|
150 %(min.)
|
Longitudinal
shrinkage
|
UL 224
|
0 to -10%
|
Heat
shock
|
225℃, 4hrs.
|
No cracking,
No dropping
|
Cold bend
-30℃, 1hr.
|
ASTM D 2671
|
No cracking
|
Voltage
withstand AC 2500V,60 seconds
|
ASTM D 2671
|
No breakdown
|
Volume
resistance
|
ASTM D 876
|
1014Ω․cm(min.)
|
Flammability
|
SAE-AMS-DTL-23053/5
|
Self extinguish in 30 sec.
|
Copper
corrosion 158℃, 168hrs.
|
UL 224
|
pass
|
Water
absorption
|
ASTM D 570
|
<0.5%
|
Adhesive
to aluminum
|
ASTM D 2671
|
60N/25mm
|
Fluid
resistance
|
Tensile strength:7MPa(min) Elongation:300%(min)
|
24hrs at 23℃ In diesel and Lubricating oil
|
|
|