HTV200
200℃
very flexible modified fluoroelastomer tubing (Viton®)
Technical Data |
Property
|
Test Method
|
Typical Data
|
Operating temperature
|
IEC 216
|
-55℃ to +200℃
|
Un-aged
|
Tensile strength
|
ASTM D 2671
|
Min.8.5
MPa.
|
Elongation
|
ASTM D 2671
|
Min.250%
|
After Aging
|
Elongation
|
250℃,168 hrs.
|
Min.200%
|
Heat shock
|
300℃,4 hrs.
|
No cracking or dropping
|
Flexibility
|
ASTM D 412
|
Max. 13.8MPa
|
Dielectric Strength
|
ASTM D 2671
|
Min. 7.9KV/mm
|
Volume resistance
|
ASTM D 876
|
Min. 109Ω.cm
|
Copper corrosion
|
SAE-AMS-DTL-23053/13
(175℃,16hrs.)
|
No corrosion
|
Flammability
|
ASTM D 2671
|
Self-extinguish in 15 sec.
|
|
|